Continuous Glucose Monitoring System
The GlucoMen Day® CGM is a real-time subcutaneous Continuous Glucose Monitoring System. Thanks to the unique GlucoMen Day® CGM Sensor technology the tiny Sensor wire is inserted under the skin without any guide needle, with reduced risk of insertion pain and bleeding.
The electrochemical enzymatic Sensor measures the glucose level in the interstitial fluid for 14 days, and the data are stored in the Transmitter and sent via Bluetooth to the dedicated App, which displays a new glucose value every minute.

Continuous Glucose Monitoring System
The GlucoMen Day® CGM is a real-time subcutaneous Continuous Glucose Monitoring System. Thanks to the unique GlucoMen Day® CGM Sensor technology the tiny Sensor wire is inserted under the skin without any guide needle, with reduced risk of insertion pain and bleeding.
The electrochemical enzymatic Sensor measures the glucose level in the interstitial fluid for 14 days, and the data are stored in the Transmitter and sent via Bluetooth to the dedicated App, which displays a new glucose value every minute.

TUTORIALS & GUIDES
FEATURES
TECHNICAL SPECIFICATIONS
THE GlucoMen® Day APP
CLINICAL DATA
TUTORIALS & GUIDES
FEATURES
TECHNICAL SPECIFICATIONS
THE GlucoMen® Day APP
CLINICAL DATA
Tutorial & Guides
VIDEOS
PDFS
Tutorial & Guides
VIDEOS
PDFS
Features

14 Day
Sensor Life
Sensor wear duration of 14 days.

Needle-free
Sensor Insertion
The Sensor wire can be inserted under the skin without any guide needle.

1 New Value
Every Minute
1 new glucose value displayed every minute.

Customizable
Alarms
Real-time alarms for high/low glucose levels, rapidly changing glucose, and predictive alarms.

Cloud Data
Sharing
Real- time cloud data sharing.

Eco
Friendly
All of the devices of the system are reusable, drastically reducing the waste of materials.
System Components


The GlucoMen Day® App
The GlucoMen Day® CGM dedicated App (for both Android and iOS smartphones) displays the latest glucose value (a new value every minute), trend arrow and glucose graph. The App allows the user to set and customise alarms for high and low glucose, rapid glucose change, and predictive alarms.
Data can be shared in real-time on a certified cloud, and accessed remotely by an authorised HCP or carer. Data analysis includes Time In Range, Average, SD, CV% and AGP, and can be performed directly by the App or by the GlucoLog web software.

Technical Specifications
Sensor + Transmitter Size: 3.5 x 2.5 x 0.9 cm
Sensor Duration: 14 days
Sensor Warm Up Time: 55 min
Measurement Frequency: 1 min
Waterproofness: IP27
Sensor Storage Temperature: 5-35 °C
Calibration: 1/day (2 for day 1 only). For the calibration a dedicated glucose meter (GlucoMen Day METER) is provided for free with the Devices Kit, and 25 strips are provided for free with every CGM Sensor.
Intended Populations: Adults, Children (6+), pregnant women, persons on dialysis, and persons who are critically ill. Measuring Principle: Electrochemical measurement by wire-type GOD-based biosensor Measuring Site: Subcutis (interstitial fluid)
Insertion Area: Abdomen
Insertion Mechanism: Automatic
Insertion Type: Needle-free (sensor is inserted without any guide-needle)
Inserter Use Life: Reusable (up to 5 years)
Use Life: Reusable (up to 5 years)
Battery Type: Rechargeable
Recharge Time: up to 4 hours
Memory: 15 days of data
Transmission Distance: 3m
Transmission Type: Bluetooth Low Energy
Data Sharing: Cloud, email
Alarms: High/low glucose, rapid glucose change, predictive alarms
App Compatibility: Android and iOS
Data Analysis Software: GlucoLog, Diasend
Available Data Analysis (from App and Software): AGP, Time in Range, Average, SD, CV%
Clinical Data
Sensor Insertion Pain Assessment
Pain perception distribution over a pain scale of 0-20, comparing the GlucoMen Day® CGM Sensor insertion vs a finger prick (1).
The GlucoMen® Day CGM Sensor insertion pain has been reported to be on average 1.3 over a pain scale of 0-20. As a reference, finger pricking had an average score of 4.9 (1) GlucoMen Day CGM Technical File, CEVAL Study.
Skin Irritation Assessment
Results of skin irritation assessment after Sensor removal (1)
During the clinical trials no adverse events (Draize score ≥4) occurred both for erythema and oedema at the insertion site or under the adhesive. (1) GlucoMen Day® CGM Technical File, CEVAL Study.